The cover of the antibacterial light features a coating that is applied uniformly to the surface in multiple layers.
These layers are comprised of “nano silver” that generates “nano ions” and “titanium oxide” that activates a photocatalytic effect.
The electricity and light emitted from a cold cathode fluorescent lamp (CCFL)acts on this antibacterial layer to exert an antibacterial effect.
Nano-silver ions, which are smaller than bacteria and viruses, can penetrate the cell membrane to make it unable to breathe, metabolize, and reproduce, and achieve the effect of sterilization.
It is effective against more than 650 kinds of viruses, bacteria and fungi, encountered in daily life.
Active oxygen is generated by the photocatalytic effect of titanium oxide to oxidatively decompose dirt and hazardous substances.
Furthermore
Demonstration experiments were conducted at several international accreditation bodies.
Experiments have proved its effectiveness against various dangerous bacteria, viruses and more.
We referenced Virus Pathology Conclusions Ver. II Maruzen Co., Ltd., Virus Neutralization Test Methods for tests.
① Treatment of test virus solution:
・Created test solution by inserting 10mL of test virus solution into a plastic petri dish (9cm diameter) (height of test virus solution inside the petri dish: Approx. 3mm)
・For the test category, we placed the test product inside a clean booth and placed the petri dish containing the test solution directly below it, then adjusted the test product light portion so that it was 30cm from the test solution surface.
・Removed the petri dish lid to start the test and then recovered virus solution from the petri dish after test start, at 4 hours from test start, and 8 hours from test start to measure virus concentration.
・For the control category, the test sample was placed on the clean bench without irradiating it, with samples taken at the same intervals. (Test environment temperature: 25°C ±2°C)
② Virus concentration measurement:
Each test solution that reached the stipulated sensitivity time for each test category was diluted by a factor of 10, then 100uL was introduced to cells cultivated on a 96well plate.
Determination was made conducting carbon dioxide gas cultivation (5%) at 37°C over five days, used a microscope to observe cultivated cells to confirm whether or not there was cytopathic effect (CPE) cell virus reproduction in the cultivated cells, and then measured concentration levels.
Conducted at the Food Environmental Sanitation Research Institute Co., Ltd., ISO17025 accredited organization.
Diluted influenza virus culture supernatant with phosphate buffer solution at a rate of 10:1 to create the virus solution.
The virus concentration of the irradiated area and un-irradiated area was measured separately after 0・4・8 hours.
Conducted at the Food Environmental Sanitation Research Institute Co., Ltd., ISO17025 accredited organization.
Since norovirus cannot be cultured, a similar species of cat influenza virus was used, which has been diluted with the phosphate buffer solution at a rate of 10:1 is used.
The virus concentration of irradiated area and unirradiated area was measured separately after 0・4・8 hours.
Conducted at the Food Environmental Sanitation Research Institute Co., Ltd., ISO17025 accredited organization.
Aspergillus Niger, Penicillium griseus, and black mold was cultured with dextrin potato starch.
The spores were then suspended in physiological saline, and about 1 million various molds per milliliter were taken and mixed to create the test solution.
The fungi concentration of irradiated area and unirradiated area was measured separately after 0・4・8 hours.
Furthermore
The deodorizing effect has been verified!
Conducted at the Food Environmental Sanitation Research Institute Co., Ltd., ISO17025 accredited organization.
An air circulator was used to stir high-concentration gas with 28% ammonia content in a 1 cubic meter container for the test.
The concentration of the experimental area irradiated by the antibacterial light (test category) and the non-irradiated experimental area was measured after 30 minutes, and one hour.
Antibacterial light / Deodorization / Eliminate Mold / Energy-Saving / Long-lasting
Therefore
We have received good reviews from customers who use our products!
In the kitchen area with advanced cooking equipment, 250 antibacterial lamps have been installed. Because of their sterilization and anti-mold effects, they can provide a safer and more hygienic working environment. Simply turn on the light and the sterilization effect can be achieved, which is very satisfactory.
After being used in the kitchen, canteen, and bathroom, a clean and hygienic environment is maintained more easily. Especially in the bathroom and other places with heavy moisture, the anti-mold effect has exceeded expectations.
The antibacterial lamps were installed in the treatment room, waiting room and toilet. The next day, a patient emailed that the smell of the toilet was way more pleasant than before. In addition, there was no construction noise while the lamps were installed. Now patients and staff can enjoy a cleaner and more comfortable environment.
Antibacterial lamps have been installed in children’s restrooms, canteens, recreation rooms and other places.
It helped us to create a relaxing and gentle space, with the benefits of preventing irritating odors and various infections.
We can really feel the odors and bacteria are greatly reduced.
Therefore
Good for the environment and wallet
Saving electricity・Long service life !!
Power consumption | Reduction ratio (for fluorescent lamps) |
Lifespan | Product Lifespan (8h✕365 days) |
Electricity bill reduction※2 (8h✕365 days) |
|
---|---|---|---|---|---|
General fluorescent lamp (FL40) | 43.5w | ------ | 8,000h | 2.74years | 3,430 yen/year |
Single-ended compact fluorescent lamp (Hf32) |
32w | 26% off | 12,000h | 4.11years | ▲907yen/year |
LED fluorescent lamp (standard product) |
23w | 47% off | 40,000h | 13.7年 | ▲1,616yen/year |
CCFL antibacterial fluorescent lamp (40w fluorescent lamp type) |
25w | 43% off | 40,000h | 13.7years | ▲1,459yen/year |
(※1) The above values are estimated values in common environments
(※2) Calculated as 27.5 yen per kilowatt-hour
Power consumption
About the same as LED, which is 43% of ordinary fluorescent.
Power consumption Lifespan
The lifespan reaches 40,000 hours the same as LED.
Antibacterial effect
Even after the light is turned off, the silver ions continue moving through the air, granting an antibacterial effect.
Coating lifespan
Titanium oxide and silver nano-coating
no need to replace the coating!
Acquired utility model in Japan. No.U3188344
Model: CCFL-11HV (white)
Specification: Color white(5,000k), Luminous Flux 600lm, PSE/EMICertification
AC IN: AC100-240V, Power 11W, Lanmp Holder E26
Size: Diameter 64mm, Total Length 129mm, Weight 96g
Lifespan: 30,000h
Quality Assurance: 2 years
Model: CCFL-11HV (Yellow)
Specification: Color white(5,000k), Luminous Flux 600lm, PSE/EMICertification
AC IN: AC100-240V, Power 11W, Lanmp Holder E26
Size: Diameter 64mm, Total Length 129mm, Weight 96g
Lifespan: 30,000h
Quality Assurance: 2 years
Model: CCFL-BAR120WFL5
Specification: Color white(5,000k), Luminous Flux 4200lm(typical), PSE/EMI Certification
AC IN: AC100-240V(50/60Hz), Power 42W±10%
Size: Diameter 1,250mm, Width 230mm, Total Length 63mm, Weight 2.8kg
Lifespan: 40,000h
Quality Assurance: 2 years
Model: 20D-12HV
Specification: Color white(5,000k), Luminous Flux 700lm(typical), PSE/EMI Certification
AC IN: AC100-240V, Power 12W, Lamp holder G13
Size: Diameter 32(30)mm, Width 580mm, Weight 180g
Lifespan: 40,000h
Quality Assurance: 2 years
Model: 40D-25HV
Specification: Color white(5,000k), Luminous Flux 700lm(typical), PSE/EMI Certification
AC IN: AC100-240V, Power 25W, Lamp holder G13
Size: Diameter 32(30)mm, Width 1,198mm, Weight 310g
Lifespan: 40,000h
Quality Assurance: 2 years
Model: CCFL-D12W [white]
Specification: white(5,000k), 520lm, PSE/EMI Certification
AC IN: AC100-240V, Power 12W
Size: Diameter 180(140)mm, High 53mm, Weight 300g
Lifespan: 30,000h
Quality Assurance: 2 years
Model: CCFL-D12W [Yellow]
Specification: white(2,700k), 520lm, PSE/EMI Certification
AC IN: AC100-240V, Power 12W
Size: Diameter 180(140)mm, High 53mm, Weight 300g
Lifespan: 30,000h
Quality Assurance: 2 years
Model: CCFL-D12W [white]
Specification: white(5,000k), 480lm, PSE/EMI Certification
AC IN: AC100-240V, Power 10W
Size: Diameter 140(100)mm, High 53mm, Weight 220g
Lifespan: 30,000h
Quality Assurance: 2 years
Model: CCFL-D12W [Yellow]
Specification: white(5,000k), 480lm, PSE/EMI Certification
AC IN: AC100-240V, Power 10W
Size: Diameter 140(100)mm, High 53mm, Weight 220g
Lifespan: 30,000h
Quality Assurance: 2 years
Model: S2T-UVA6W [UV Bug Lamp]
Specification: CCFL UV Lamp Range Effect 48-70㎡
AC IN: AC100V, Power DC12V 6W
Size: Length 360mm, High 200mm, Width 170mm, Weight 820g
Lifespan: 15,000h
Quality Assurance: 2 years
Model: CCFL-SLWH24
Specification: white(6,000k), Luminous Flux 700lm
AC IN: DC24V 0.5A(Rate), Power 12W
Size: Length 420mm, Width 182mm, High 23mm, Weight 570g
Lifespan: 30,000h
Quality Assurance: 2 years
Model: CCFL-SLWH12
Specification: white(6,000k), Luminous Flux 700lm
AC IN: DC12V 1.0A(Rate), Power 12W
Size: Length 420mm, Width 182mm, High 23mm, Weight 570g
Lifespan: 30,000h
Quality Assurance: 2 years
Model: CCFL-NSWH12
Specification: white(6,000k), Luminous Flux 700lm
AC IN: DC12V 1.0A(Rate), Power 12W(With DC Cigar Plug)
Size: Length 360mm, Width 145mm, High 23mm, Weight 550g
Lifespan: 30,000h
Quality Assurance: 2 years
Please be careful of counterfeit products, our products have obtained utility model patents.